Gestra, Rotork, Daniel, Georg Ficher, Agar, Sofis, Pump, Valves

Product detail

Magnetic Flowmeter

Versaflow Mag 100:
Size: DN10 to DN150
Accuracy up to 0.2 %
Process connection: Flanges for DIN, ANSI & JIS, Max pressure PN40
Temperature: -25 to 120oC
IP 66/67 eq. NEMA 4/4X / 6 or IP 68 eq. NEMA 6 
Measuring tube material:  Austenitic stainless steel/PFA lined
Housing sheet steel  or GTW-S 38 (polyurethane coated) 
Electrodes: Hastelloy C4
Converter: Compact + TWM 100 C or Separate + TWM 300 F, R, W, cable max 600m

 

Versaflow Mag 1000:

Size: DN25 to DN2000
Accuracy up to 0.2 %
Process connection: Flanges for DIN, ANSI & JIS, Max pressure PN40
Temperature: -5 to 90oC
IP 66/67 eq. NEMA 4/4X / 6 or IP 68 eq. NEMA 6/6P
Approval: EEx zone 1, FM - class I div. 2, CSA – class l div.2 etc…
Measuring tube material:  SS316 or Austenitic stainless steel/Polypropylene or Hard Rubber
Housing: Sheet steel (polyurethane coated) or SS316
Electrodes: SS316Ti, Hastelloy C4, Hastelloy C22, Titanium
Converter: TWM 1000 Compact/Separate or TWM 9000 Compact/Separate, cable max 600m

 

Versaflow Mag 3000:
Size: DN10 to DN150
Accuracy up to 0.2 %
Process connection: DIN11850, ISO 2037, Dairy screw to DIN 11851, Screwed to SMS1145, Flanges to DIN 11864-2A , Tri Clamp, Max pressure PN40
Temperature: -40 to 140oC
IP 66/67 eq. NEMA 4/4X / 6 or IP 68 eq. NEMA 6/6P
Approval: EEx zone 1, FM - class I div. 2, CSA – class l div.2 etc…
Measuring tube material:  SS316 or Austenitic stainless steel/Polypropylene or Hard Rubber
Housing: Sheet steel (polyurethane coated) or SS316
Electrodes: SS316Ti, Hastelloy C4, Hastelloy C22, Titanium, Tantalum
Converter: TWM 1000 Compact/Separate or TWM 9000 Compact/Separate, cable max 100m

 

Versaflow Mag 4000:
Size: DN2.5 to DN2000
Accuracy up to 0.2 %
Process connection: DIN, JIS & ASME B16.5 (150lbs RF to 1500lbs RF)
Temperature: -40 to 140oC
IP 66/67 eq. NEMA 4/4X / 6 or IP 68 eq. NEMA 6/6P
Approval: EEx zone 1, FM - class I div. 2, CSA – class l div.2 etc…
Measuring tube material:  SS316 or Austenitic stainless steel/ Liner PU (Irathane) Hard Rubber, PTFE, ETFE, PFA
Housing: Sheet steel (polyurethane coated) or SS316
Electrodes: SS316Ti, Hastelloy C4, Hastelloy C22, Titanium, Tantalum, Low noise HC4, Platinum
Converter: TWM 1000 Compact/Separate or TWM 9000 Compact/Separate, cable max 600m

 

Versaflow Mag 2000:

Size: DN2.5 to DN100
Accuracy up to 0.15 %
Process connection: DIN, JIS & ASME B16.5 (150lbs RF to 300lbs RF)
Temperature: -60 to 180oC
IP 66/67 eq. NEMA 4/4X / 6 or IP 68 eq. NEMA 6/6P
Approval: EEx zone 1, FM - class I div. 2, CSA – class l div.2 etc…
Measuring tube material: Ceramic
Housing: Duplex (1.4462), AISI 304 (1.4306), Flow sensor housing (PU coated)
Electrodes: Cermet & Platinum 
Converter: TWM 1000 Compact/Separate or TWM 9000 Compact/Separate, cable max 600m

 

Versaflow Converter TWM 1000:

TWM 1000 C (compact), W (Remote Mounted)
Accuracy up to 0.3%
Full-scale range: v = 0.3...12 m/s / 1...40 ft/s
Temperature: -50 to +70°C 
IP 66/67 for Compact & Remote
EEx zone 1, FM - class I div. 2, CSA – class l div.2 etc…
Housing: Sheet steel (polyurethane coated) or SS316, cable connection ½" NPT, M20
Display: 2 measured value pages, 1 status page, 1 graphic page (measured values and depictions adjustable as required) 
Output:  Current (incl. HART®), pulse, frequency, status output and/or limit switch, 2 internal counters with a max. of 8 counter places (e.g. for counting volume and/or mass units)
Sensors: Mag 100, Mag 1000, Mag 3000, Mag 4000 & Mag 2000 max cable 600m
Power supply: 100…230 VAC 50/60 Hz, 24 VAC/VDC

 

Versaflow Converter TWM 9000:

TWM 9000 C (compact or Integrally Mounted), F (field), W (wall), R (19" rack, Remote Mounted)
Accuracy up to 0.15% to 0.2 %
Full-scale range: v = 0.3...12 m/s / 1...40 ft/s
Temperature: -50 to +70°C 
IP 66/67 for Compact or Field, IP65 for Wall and IP20 for 19” Rack
EEx zone 1, FM - class I div. 2, CSA – class l div.2 etc…
Housing: Sheet steel (polyurethane coated) or SS316, cable connection ½" NPT, M20
Display: With local display (2 meas. pages: 1 status page, 1 graphical page)
Output: Current, pulse & status output, frequency output, limit switch, HART, control input, 3 counters, Modbus, Foundation Fieldbus, Ex-i
Sensors: Mag 100, Mag 1000, Mag 3000, Mag 4000 & Mag 2000, max cable 600m
Power supply: 100…230 VAC 50/60 Hz, 24 VAC/VDC

 

 

 

 

 

 

 

Other Services

Gestra, Rotork, Daniel, Georg Ficher, Agar, Sofis, Pump, Valves