Features :
Specifications :
-Display
Type | High intensity transflective numeric and alphanumeric LCD, UV-resistant, with bright backlight. Intensity can be adjusted via the keypad. |
Note | When battery powered, the backlight is only operational after a keypad touch, to extend battery lifetime. |
Dimensions | Ø 65 x 45mm (2.56” x 1.77”) |
Digits | Seven 12mm (0.47”) and eleven 7mm (0.28”) digits. Various symbols and measuring units. |
Refresh rate | User definable: 8 times/sec. – 30 secs |
Speedometer | To indicate the actual flow rate the bargraph runs from 0 to 100% in 20 blocks, each block is 5% |
Ambient | -40°C to +70°C (-40°F to +158°F) |
Type PB | Long life Lithium battery – lifetime depends upon settings and configuration – up to approx. 3 years |
Note PB | The battery can power the backlight for a short time after a keypad touch but cannot power the relay output (OR) or the real sensor supply (Terminal P3) |
Type PD | 9 – 27V DC. Consumption max. 4.5 Watt |
Type PX | 9 – 27V DC. Consumption max. 3 Watt |
Type AH | Loop powered, analog output. 11 – 27V DC, Min. 3.5mA. Consumption max. 675mW (25mA @ 27VDC) |
Note AH | The loop powered analog output cannot power the backlight, mechanical relay output (OR) or the real sensor supply (Terminal P3) |
Type AH/PB/PX | Terminal S3: 3V DC for pulse signals and 1.2V DC for coil pick-up, Iout max. 100μA |
Note AH/PB/PX | This is not a real sensor supply. Only suitable for sensors with a very low power consumption like coils (sine wave) and reed-switches |
Type PD | Terminal P3: 8.2 / 12 / 24V DC 8.2V DC, Iout max. 20mA 12V DC, Iout max. 30mA 24V DC, Iout max. 75mA (this voltage varies depending on the input supply voltage) |
Type | Removable plug-in terminal strip. Wire max. 1.5mm2 and 2.5mm2 |
Type | EEPROM backup of all settings. Backup of running totals every minute. Data retention at least 10 years. |
Password | Configuration settings and clear total can be password protected. |
EMC | Directive 2014/30/EU, FCC 47 CFR part 15 |
Low voltage | Directive 2014/35/EU |
RoHS | Directive 2011/65/EU |
ATEX / IECEx | Directive 2014/34/EU, IEC 60079-0, IEC 60079-1, IEC 60079-31 |
FM | Class 3600, 3615, 3616, 3810 |
CSA | CSA 22.2 No. 25, No. 30, No. 61010-1-12 |
UL | UL 61010-1 |
IP & NEMA | EN 60529 & NEMA 250 |
Ambient Temp | -40°C to +70°C (-40°F to +158°F) |
ATEX certification | Gas: II 2 G Ex d IIC T6 Gb Dust: II 2 D Ex tb IIIC T85°C Db |
IECEx certification | Gas: Ex d IIC T6 Gb Dust: Ex tb IIIC T85°C Db |
FM & CSA c-us certification | Class I, Div. 1, Grps A, B, C, D Certification Class II/III, Div. 1, Grps E, F, & G Class I, Zone 1, AEx d IIc T6 Gb, Zone 21, AEx tb IIIC T85°C Db |
Window | Glass window |
Sealing | Silicone |
Control keys | Three infra-red keys with operation through the glass front window |
Rating | IP66, IP67 / NEMA Type4X / Type7 / Type9 |
Dimensions | 112 x 133 x 148mm (4.41” x 5.24” x 5.83”) – W x H x D |
Type HA_ | Aluminum Ex d enclosure |
Weight | 1550 gr. (3.41 lbs) |
Type HS_ | Stainless steel 316L Ex d enclosure (Consult factory) |
Weight | 3600 gr. (9.65 lbs) (Consult factory) |
Type H_D | Entry threads: 2 x 1/2”NPT / 1 x 3/4”NPT |
Type H_G | Entry threads: 2 x M20 / 1 x M25 (Consult factory) |
Type H_H | Entry threads: 3 x M25 (Consult factory) |